PureAire Monitoring

Air Check Multi Channel Controller

ST-71 16 Channel Modbus® Master Display & Alarm Monitor/Controller
  • 16 Channel Multi gas Controller
  • Controls any 2 wire or 3 wire gas sensors
  • User selectable dual level concentration alarms
  • Digital and bargraph gas concentration display
  • Graphical display of detector system faults
  • Optional Modbus output

PureAire’s Air check Multichannel Controller is designed to provide simultaneous display and alarm functions for up to 16 gas monitors. A graphic LCD displays monitors data as trends, bar graphs and ppm, ppb or percent gas concentration. Three adjustable alarm levels are provided per channel. Relay outputs allow control of strobe beacons horns and other shutoff devices.

The Air Check Controller is user friendly and easy to configure. Measurement ranges in engineering units, adjustable alarm set-points, dual serial interfaces and many other features combine to allow the ST-71 satisfy the needs of many demanding applications. It is widely used for centralizing the display and alarm processing functions in critical multipoint monitoring applications. These include monitoring of ambient gas detection, rotating machinery, tank levels, flow, temperature and others.

A RS-485 Modbus slave port allows up to 128 Air Check controllers to be multidropped onto a single data highway for interrogation by another Modbus master. PureAire’s multi channel controller may also be cascaded by connecting one unit’s master port to another’s slave port.

Performance Specifications

Input Signals: 4-20 mA, 8 to 16 individual PureAire gas monitors
Relay Outputs:  Two alarm SPDT relays and one system fault SPDT relay per channel       
Relay Capacity: 5 Amp for 28 VDC and 250 VAC resistive load
Serial Communication: Optional Dual Modbus RS-485 serial ports for simultaneous master / slave operation.     
Display: Graphic LCD readout displays monitored data as trends, bar graphs and gas concentration. Alarm LED’s flash when new and become steady after acknowledged
Operating Temp: -25° to 50°C, (-13° to 122°F)
Humidity: 0 TO 90% RH Non-Condensing.

Electrical Requirements

Power: 110-120 VAC @3.2A max (220-240VAC @ 1.6A max)

Physical Characteristics

Installation Style: NEMA 4X, Explosion-Proof, surface mount, panel and rack mount packaging options available NEMA 4X wall mount in fiberglass enclosure, weight 17 lb 14.25” L x 13” W x 8.5” D  NEMA 7 wall mount suitable for DIV 1&2 Groups B,C,D weight 110 lbs.

Approvals

CSA C22.2 No 1010.1 and ISA S82.02; CSA C22.2 No 152 for combustibles; UL 1604 C22.2 No 213 (Div 2 Groups A,B,C,D); EN55011 & EN61000 (CE Mark). CSA File # 219995

       