- Transmitter connects to any PureAire toxic or corrosive gas sensor
- Plug & play sensor sets the transmitter gas & measurement range
- Dual-level user-adjustable alarm relays
- 4- 20mA analog output (Active)
- Built-in horn & visual alarm LEDs
- Electronics continuously check the sensor & system status
- Low-cost, long-life renewable sensor
- Quick, easy sensor calibration
- Optional remote cable for monitoring up to 30 feet from the transmitter
- Connects to PLC or SCADA controller
- UL, CUL, and CE Approvals
- 24V DC Power supply included
- Available without a built-in horn – 99065. Please contact PureAire for ordering information: 847-726-6000
The PureAire Phosphoryl Chloride Gas Detector (POCl3)is a compact fixed gas monitor that’s ideal for protecting workers from toxic and corrosive gas exposure in the workplace. It consists of a transmitter/controller connected to a dedicated, renewable gas sensor that automatically inputs the gas and measurement range. Designed as a stand-alone monitor, the Phosphoryl Chloride Gas Detector can also be connected to any programmable logic controller or SCADA system. PureAire also manufactures toxic gas detectors with a remote sensor.
The heart of the Phosphoryl Chloride Gas Detector is a smart, renewable sensor cell programmed with gas and measurement range information. When servicing the sensors, they can be recharged with fresh electrolyte and dynamically gas-calibrated in the maintenance shop away from the transmitter.
Save Big on Annual Maintenance—Without Compromising Safety
The PureAire POCl₃ Gas Detector offers the lowest total cost of ownership in the industry, combining advanced monitoring technology with smart, budget-friendly maintenance. Instead of replacing expensive disposable sensor cells, PureAire’s renewable phosphoryl chloride sensors can be recharged in the field with fresh electrolyte—a process that costs just 20% of traditional sensor replacements. With annual maintenance averaging $70, you’ll save hundreds of dollars each year while maintaining constant protection against hazardous gas leaks.
Truly Stand-Alone Operation—Simple to Set Up, Easy to Use
No extra equipment or complicated wiring is required. The POCl₃ Gas Detector is a self-contained system—just mount it near your gas risk zone, plug it into any 115VAC or 220VAC outlet, and it’s ready to go. The detector instantly begins monitoring and features a built-in alarm horn and bright LED indicators that quickly alert personnel in the event of a gas leak. It also includes dedicated alarm and fault relays for external notification systems, and the 4–20mA analog output delivers continuous real-time data to SCADA or PLC systems.
24/7 Intelligent Monitoring—With Built-In Self-Diagnostics
This isn’t just a gas detector—it’s a smart safety system. The POCl₃ Detector uses advanced circuitry that monitors itself around the clock, so if anything goes wrong, it immediately triggers alerts through both analog output and fault relays to your control room. A microcontroller embedded in the sensor stores all calibration data, allowing the sensor to be removed from the transmitter for quick, easy maintenance. Once reconnected, the sensor automatically uploads the data back to the system, keeping your detector accurate and downtime minimal.
Smart Protection. Simple Maintenance. Real Savings.
From semiconductor manufacturing to chemical processing facilities, the PureAire POCl₃ Gas Detector is trusted for its durability, cost-efficiency, and non-stop performance. It’s the ideal solution for organizations that demand safety and value in equal measure.