Hazardous Location 5 Joule Horn & Strobe

Product Summary

The PureAire Hazardous Location Horn & Strobe combines a 114dB horn with a 5 Joule Xenon strobe to provide a complete audio-visual signaling solution for hazardous locations. The lightweight, corrosion-proof, GRP enclosure is specifically designed for the harshest environments.

The Horn and Strobe is ideal for facilities including oil and gas, petrochemical, pharmaceutical, biotechnology, semiconductor, wastewater treatment, solvent manufacturing and in any locations where hazardous toxic, flammable gases are present.

The horn and strobe is compatible with PureAire’s line of oxygen monitors, toxic and corrosive gas detectors. It can be connected to a programmable logic controller (PLC) to provide visual and audible alerts throughout the facility.

Part# 42018 – Hazardous Location 5 Joule Horn & Strobe

Please contact PureAire at (847)726-6000 for more information, including pricing and availability.

FEATURES

  • 114dB horn with 45 on-board tones
  • 5 Joule Xenon strobe, tube secured against vibration/shock
  • Stainless steel dome guard
  • Ratchet adjustable stainless steel “U” bracket
  • Enclosure UL94V0 GRP (PPS) & ABS
  • Borosilicate glass dome with PC prismatic lens cover
  • Corrosion resistant GRP enclosure
  • Enclosure – IP rating per EN60079-0: IP64, IP rating per EN60529: IP66, Type rating per UL50E/NEMA250: 4/4X/13
  • Operating temperature range: -4°F to +131°F (-20°C to +55°C)
  • 24 VDC

APPROVALS

  • ATEX certificate: DEMKO 06 ATEX 0421554X
  • IECEx certificate: IECEx ULD 14.0012X
  • UL/cUL File ref: E230764
  • UKCA certificate: UL21UKEX2135X
  • Ex EAC certified: EAC RU C-GB.AA71.B.00273/20

FACILITIES THAT NEED THIS PRODUCT

  • Pharmaceutical Manufacturers
  • Oil and Gas
  • Power Plants
  • Waste Water Treatment
  • Natural Gas
  • Solvents Manufacturing

Hazardous Location 5 Joule Horn & Strobe Product Literature

Hazardous Location Ready

ATEX, IECEx, UL/cUL and UKCA certified for use in hazardous areas.

Audible + Visual Alerting

114dB horn with 45 on-board tones plus a 5 Joule xenon strobe.

Built for Harsh Environments

Corrosion-resistant GRP enclosure rated IP66 / NEMA 4X.

Pairs with PureAire Products

Connects to PureAire oxygen, toxic and combustible gas monitors and to a PLC.

Oxygen deprivation is a silent killer. Oxygen-depleting gases, such as nitrogen, argon, and helium, are odorless and colorless, making leaks impossible to detect, unless appropriate monitoring is in place.

PureAire oxygen deficiency monitors can be used to monitor nitrogen, argon, and helium. Carbon dioxide can also be monitored with PureAire’s dual oxygen/carbon dioxide monitor.

PureAire uses a proprietary, non-depleting, zirconium oxide sensor that will last up to 10 years in a normal environment without needing to be replaced.

PureAire’s sensors do not operate under partial pressure, meaning that a PureAire sensor will not need to be adjusted to account for different elevations. Additionally, the sensors will not drift due to changes in barometric pressure.

In contrast, other gas detection companies use depleting, electrochemical sensors. These sensors, because they are depleting, operate for 1-2 years before needing to be replaced. Electrochemical sensors do not offer long-term solutions to companies committed to safety.

PureAire sensors are built to last 10 years. Often, the sensors work much longer. In fact, some of our first customers who started using PureAire products in 1997 report that the sensors are still in operation today.

On the other hand, an oxygen monitor that uses a depleting, electrochemical sensor is like a battery in that, as the sensor depletes, it begins to lose its power and responsiveness. In order to operate accurately, electrochemical sensors must be calibrated frequently.

PureAire sensors are made of non-depleting zirconium oxide, and calibration is typically not required.

However, a visual check of the monitor should be done once a year to verify that the sensor is functioning properly, and span adjustments should be done, as necessary. The sensor requires periodic testing with nitrogen to verify the sensor’s response to low oxygen levels.

In contrast, electrochemical sensors, because they deplete over time, will need to be calibrated every 2-3 months and totally replaced every 1-2 years.

Switching to a PureAire non-depleting, zirconium oxide sensor will save you time and money, while ensuring the safety of your workers and facility.

Electrochemical sensors offered by other gas detection companies lose accuracy over time and must be calibrated. Calibration recharges and resets the monitor to get an accurate reading. It is important to note that an electrochemical sensor can only be calibrated a finite number of times before it must be discarded.

PureAire’s non-depleting zirconium oxide sensor will not experience drift. Oxygen sensors from PureAire will provide long-lasting, reliable, and accurate monitoring for an average of10+ years.

The oxygen monitor covers an area of approximately 692 square feet when mounted on a wall and should be placed no more than 21 feet from potential leak sources such as gas lines, gas cylinders, or any areas where a gas leak might be expected to occur.

To ensure safety, the maximum distance between two monitors mounted to the same wall, should not exceed 30 feet. However, since cryogenic gases, such as argon, helium, and nitrogen, are unpredictable, we encourage you to contact PureAire for additional guidance specific to your needs.

In most circumstances, PureAire recommends that oxygen monitors be installed 3-5 feet away from gas cylinders or cryogenic gas lines. To enable employees to see the monitor display and verify its performance, PureAire recommends mounting an oxygen monitor 3-5 feet off the ground.

There are other options for mounting an oxygen monitor. For instance, PureAire sensors can sample the air from up to 100 feet away, or be installed within a glovebox, freezer, sealed chamber, or even underground. PureAire monitors can also work in environments that require KF-25 flanges, as well as in nitrogen/argon enriched environments.

PureAire’s Sample Draw Monitors pull a sample flow at a rate of 250 ccs per minute. We recommend using 1/4” OD x 3/16” ID polypropylene sample tubing. Using this internal tubing dimension, to calculate transport (response) time, add 2 seconds per foot of sample tubing. For example, if the sample tube is 10 feet long, the initial response time would be 20 seconds (10ft x 2seconds=20seconds) at 15 feet the response time would be 30 seconds (15ft x 2seconds=30seconds), etc.

The response time when using the entire 100 feet of sample tube will take 3.5 minutes (100ft x 2seconds=200seconds or 3.5minutes) for the sample to reach the monitor.