INPUT
parameter conditions/description min typ max units
voltage 90 264 Vac
frequency 47 63 Hz
current 0.8 A RMS
inrush current1 at 115 Vac, full load, cold start
leakage current 0.25 mA
no load power consumption 0.3 W
Notes: 1. 24 V model, no damage at 230 Vac, cool start
OUTPUT
parameter conditions/description min typ max units
line regulation ±1 %
load regulation ±5 %
PROTECTIONS
parameter conditions/description
short circuit protection output shut down and auto restart
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage input to output at 10 mA for 1 minute 3,000
isolation resistance input to output at 500 Vdc 100 MΩ
safety approvals UL 60950-1
EMI/EMC FCC Class B
RoHS compliant yes
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature 0 40 °C
storage temperature -10 70 °C
operating humidity 20 80 %
storage humidity 10 90 %
MECHANICAL
parameter conditions/description min typ max units
dimensions 1.1in x 3.05in x 1.11in (27.9mm x 77.5mm x 28.2mm)
weight .5lbs (.2kg)
input plug fixed US
Country of Origin: China
Harmonized Tariff Code: 8533.00.0000