Oxygen Analyzer 0-10 ppm-2

PPB Oxygen Analyzer

Item #: 99201

$5,695.00

Product Summary

PureAire’s Parts Per Billion (ppb) Oxygen Analyzer, is ideal for facilities requiring continuous monitoring of semiconductor tools, 3D printers, glove boxes, nitrogen gas lines, and vacuum chambers, as well as any locations where there is little to no oxygen present. The unit’s sensor mounts directly into the process chamber with the use of a KF-type vacuum fitting. The analyzer is well suited for semiconductor tools, OLED manufacturers, 3D printing, and, any industry applications where inert gases, including, but not limited to, nitrogen, helium, and argon are used in a vacuum. PureAire’s stable, long-life zirconium oxide sensor will last many years in maintained environments without needing to be replaced.

Two-Year Extended Warranty Available for this product in the US, Canada, and Mexico
  • 10-10,000 PPB / 0.01-10.00 PPM Oxygen Sensor
  • Accuracy ± 200 PPB of calibrated range
  • KF25 Flange Connector
  • Operates in a vacuum, 20 Torr or less
  • Leak rate of <1E-9 (or 1X10^-9) millibars (mb)/sec
  • Low Maintenance Zirconium Cell
  • 3-year warranty
  • 2 Alarm relays
  • No drift due to environmental or temperature changes
  • 24V DC Power supply included (99201)
  • International Power supply included (99216)

PureAire’s Parts Per Billion (ppb) Oxygen Analyzer is well suited for environments where little to no oxygen is present, including semiconductor tools, wafer transfer tools, process chambers, cryogenic gloveboxes, nitrogen gas lines, 3D printers, and nitrogen generators.

The PPB Trace Oxygen Analyzer comes with a 10-foot cable and a 10-plus-year zirconium oxide sensor, which can be placed inside the process or vacuum chamber for accurate readings. To monitor readings from outside, connect the sensor using a 10-foot cable or K25 flange, then check readings and adjust the environment as necessary.

Features

PureAire’s PPB Trace Oxygen Analyzer can be used indoors or outdoors. Regardless of humidity, barometric pressure, or temperature changes, the oxygen analyzer performs reliably to safeguard your business. Even with a high electromagnetic field, this analyzer can provide stable, accurate readings.

PureAire PPB Trace Oxygen Analyzers use a zirconium oxide cell rather than an electrochemical sensor for increased reliability and longer-lasting performance. The zirconium oxide sensor can last 10+ years. The zirconium oxide sensor responds in seconds to changes in oxygen levels, and will set off built-in audible and visual alarms notifying staff of low oxygen levels.

A KF-type vacuum fitting lets you mount the sensor directly into the vacuum chamber or into the load locks. By monitoring oxygen levels inside the vacuum, the Oxygen Analyzer improves thru-put, since there’s no need to use an ambient environment as a medium for measuring oxygen levels.

Rather than disposable sensors, which must be calibrated regularly to perform up to specifications, the PPB Trace Oxygen Analyzer saves time and money. Within three years, the sensor will pay for itself. Customers enjoy an average savings of $475 per year by installing the Oxygen Analyzer instead of another product.

 

Sampling Method Diffusion Oxygen Analyzer
(Supplied with KF-25 Fitting)
Gases Detected Oxygen (O2)
Range 10-10,000 PPB / 0.01-10.00 PPM Oxygen
Accuracy ± 200 PPB of calibrated range
Operating Temperature  -40º to 140ºF (-40º to 60ºC)
Display 3/4″ LCD Digital Display, Back Lit, 3 Alarms LED´s
Sensor Type Zirconium oxide
Sensor Life 10 years under normal operating conditions
Signal Outputs 4-20 mA Analog Output (Active)
Dual-Level Alarm Relay Contacts
Please contact PureAire for the available RS-485 option
Power Requirements 24 VDC
250 mA
Width 5.0 in
127 mm
Height 5.5 in
140 mm
Depth> 3.25 in
83 mm
Weight 2.1 lb
0.9 kg
Enclosure Polycarbonate
Calibration Calibration is not required. Periodic span adjustment as needed.
Country of Origin USA
Harmonized Tariff Code 8531.10.0045
Additional O2 Monitor Accessories List Price
8 Channel Controller $3,355.00 US (P/N # 99196)
Horn and Strobe  $190.00 US (P/N # 42002)

Connects to DCS and PLC Controls

The PPB Oxygen Analyzer transmits readings directly to a distributive control system or a programmable logic controller, so you can easily check oxygen concentration levels inside the vacuum.

PureAire’s Oxygen Sensor Cell

Unlike other zirconium cells, which need a reference gas to provide readouts, the PPB Oxygen Analyzer can operate without a reference gas. The Current Limiting Zirconium Oxide Oxygen sensor is superior at detecting low levels of oxygen and can be used in environments that contain no oxygen, such as 100 percent nitrogen environments.

One-Step Sensor Adjustment

PureAire Oxygen Deficiency Monitors require occasional testing with nitrogen to validate the sensor’s response to low oxygen levels. While calibration is not necessary for our monitors to accurately measure oxygen depletion levels1, annual fine-tuning might be needed to ensure the sensor’s span accurately corresponds to the standard 20.9% oxygen concentrations.

PureAire’s Auto-Span not only simplifies the process of adjusting the span of the oxygen sensor but also provides a quick check of the sensor and the monitor’s response to an oxygen-deficient atmosphere. With a press of a button, this feature saves you time and money, protects your facilities and employees, and, most importantly, provides you with the reassurance of consistently reliable performance, making it a valuable addition to your safety measures.

1Please follow your facility’s safety guidelines and state and local regulations regarding calibration requirements for safety equipment.

PPB O2 Monitor System Features

The PPb O2 Analyzer comes in different configurations. Choose between the simple display-only monitor or a fully-featured monitor that comes with user-selectable alarms. No matter which display you choose, you’ll enjoy a sophisticated CPU, reliable performance, and peace of mind.

PPB Oxygen Analyzer 0-10.00 ppm Literature

PPB Oxygen Analyzer 0-10.00 ppm Manual

Calibration & Repeatability Testing 0-10.00 ppm

Safety Risks of Oxygen Deficiency

NIH – Protocol for Use & Maintenance of Oxygen Monitoring Devices 2021

Oxygen Analyzer for 3D Printers- Additive Manufacturing

How to Install O2 Sensor into a 3D Direct Metal Printer (DMP)

How to Install O2 Sensor in 3D Direct Metal Printer 

Oxygen Monitor Sales Presentation

Horn/strobe 24VDC Red

horn and strobe

CloudConnect

8-Channel Controller for Oxygen, Carbon Dioxide, or Toxic/Combustible Gas Monitors